Data Entry

<< Click to Display Table of Contents >>

Navigation:  Appendix A Examples > Example 15: Leachate Collection with Failure >

Data Entry

Previous pageReturn to chapter overviewNext page

Open the Examples project and open Case 15.

 

 

General Tab

 

clip0299

 

The general data for this example is the same as for Case 14, except that the title is different.

 

 

Layers Tab

 

clip0300

 

The layer data for this example is the same as for Case 14

 

 

Boundaries Tab

 

clip0301

 

The boundary conditions for this example is the same as for Case 14.

 

 

Special Features

 

The time-varying data and passive sink data for this model can be entered using the Time-varying Properties option in the Special Features tab. When both of these are options are selected the passive sink data is entered as part of the time varying properties.

 

 

Time Varying Properties

 

To specify the time-varying properties, check the Time-Varying Properties box on the Special Features tab. The Time-Varying Data sub-tab is used to specify the time period data and whether there are variable layer properties and variable decay. In this example there are 5 time periods.

 

clip0302

 

In the first time period, specifying only one time increment means that the concentrations will only be calculated at the end time (i.e., 20 years). The Darcy velocity is set to one here and will be entered in the Passive Sink property on the left. Since this is the first time period the primary leachate collection system is still functioning and there is no increase in any of the above parameters.

 

 

clip0303

 

The data for the second time period, from 20 to 30 years, can be specified by pressing the Next arrow. The increment in the Leachate collected results from the increasing Darcy velocity during this period. This increase in Darcy velocity will be taken into account in the Passive Sink property on the left side.

 

 

clip0304

 

Next the data for time period three from 30 to 50 years can be entered.. Two increments are used to calculate the concentrations at 40 and 50 years. At this point the primary leachate collection system has completely failed and there is no further increase in the Darcy velocity. The Volume of Leachate collected is now equal to the infiltration through the cover 0.3 m/a minus the final Darcy velocity 0.1 m/a.

 

 

clip0305

 

The data for time period four should can be entered by clicking on the next arrow. Five increments are used to calculate the concentrations at 60, 70, 80, 90, and 100 years.

 

 

clip0306

 

Finally the data for time period five is entered.. Five increments are used to calculate the concentrations at 120, 140, 160, 180, and 200 years.