<< Click to Display Table of Contents >> Model Output |
After the model has been executed, the output for the model will be displayed.
Concentration vs Depth
The Concentration vs. Depth chart can be displayed by selecting the Concentration vs Depth item for the Chart Type.
Output Listing
To display the output as a text listing that will show the calculated concentrations as numbers, click on the List tab.
POLLUTEv8
Version 8.00 Beta
Copyright (c) 2021
GAEA Technologies Ltd., R.K. Rowe and J.R. Booker
Case 2: Pure diffusion
THE DARCY VELOCITY (Flux) THROUGH THE LAYERS Va = 0 m/year
Layer Properties
Layer |
Thickness |
Number of Sublayers |
Coefficient of Hydrodynamic Dispersion |
Matrix Porosity |
Distributon Coefficient |
Dry Density |
Aquitard |
4 m |
4 |
0.01 m²/a |
0.4 |
0 cm³/g |
1.5 g/cm³ |
Boundary Conditions
Constant Concentration
Source Concentration = 1 mg/L
Constant Concentration Bottom Boundary
Base Concentration = 0 mg/L
Laplace Transform Parameters
TAU = 7 N = 20 SIG = 0 RNU = 2
Calculated Concentrations at Selected Times and Depths
Time |
Depth |
Concentration |
10 |
0.000E+00 |
1.000E+00 |
|
1.000E+00 |
2.535E-02 |
|
2.000E+00 |
7.744E-06 |
|
3.000E+00 |
2.011E-11 |
|
4.000E+00 |
0.000E+00 |
50 |
0.000E+00 |
1.000E+00 |
|
1.000E+00 |
3.173E-01 |
|
2.000E+00 |
4.550E-02 |
|
3.000E+00 |
2.699E-03 |
|
4.000E+00 |
0.000E+00 |
100 |
0.000E+00 |
1.000E+00 |
|
1.000E+00 |
4.795E-01 |
|
2.000E+00 |
1.573E-01 |
|
3.000E+00 |
3.349E-02 |
|
4.000E+00 |
0.000E+00 |
150 |
0.000E+00 |
1.000E+00 |
|
1.000E+00 |
5.636E-01 |
|
2.000E+00 |
2.477E-01 |
|
3.000E+00 |
7.937E-02 |
|
4.000E+00 |
0.000E+00 |
200 |
0.000E+00 |
1.000E+00 |
|
1.000E+00 |
6.166E-01 |
|
2.000E+00 |
3.146E-01 |
|
3.000E+00 |
1.212E-01 |
|
4.000E+00 |
0.000E+00 |
NOTICE
Although this program has been tested and experience would indicate that it is accurate within the limits given by the assumptions of the theory used, we make no warranty as to workability of this software or any other licensed material. No warranties either expressed or implied (including warranties of fitness) shall apply. No responsibility is assumed for any errors, mistakes or misrepresentations that may occur from the use of this computer program. The user accepts full responsibility for assessing the validity and applicability of the results obtained with this program for any specific case.