<< Click to Display Table of Contents >> Source and Hydraulic Heads |
To edit the source and hydraulic head data for a model click on the Source and Hydraulic Heads tab on the left side of the model form.
The source parameters are the same as those for a Primary Landfill Model and are described in that section.
Hydraulic Heads
Infiltration in to Attenuation Layer: This is the downward infiltration due to precipitation in the attenuation layer (aquitard). The infiltration will have the effect of removing contaminant by acting as a passive sink with inflow. To avoid this effect set the infiltration into the attenuation layer to zero.
Head in the Waste: This is the head in the waste, relative to the same datum (depth) as the head in the attenuation layer (aquitard).
Head in the Aquitard: This is the head in the aquitard (attenuation layer) at a location outside of the barrier (liner system).
Distance between Head Measurements: This is the horizontal distance between the two head measurements above.