WEBVTT

00:00:00.400 --> 00:00:01.890
Welcome to Ask GAEA.

00:00:02.845 --> 00:00:05.590
This guide shows how to record Total Core Recovery and

00:00:05.605 --> 00:00:08.390
Rock Quality Designation for the same run in

00:00:08.405 --> 00:00:09.470
GaeaSynergy.

00:00:11.625 --> 00:00:15.230
From the project Dashboard, open the intended rock-core

00:00:15.245 --> 00:00:19.210
log. Check the borehole ID and depth units against the

00:00:19.225 --> 00:00:22.890
run sheet. Find the Total Core Recovery and Rock

00:00:22.905 --> 00:00:26.970
Quality Designation columns. Depending on the template

00:00:27.125 --> 00:00:29.090
they can appear as numbers or bars.

00:00:32.265 --> 00:00:35.450
For each run, subtract its top depth from its bottom

00:00:35.465 --> 00:00:38.730
depth. Divide the total recovered length by the run

00:00:38.745 --> 00:00:40.730
length for Total Core Recovery.

00:00:43.625 --> 00:00:46.510
Divide the combined length of qualifying sound pieces

00:00:46.525 --> 00:00:49.510
by the same run length for Rock Quality Designation.

00:00:52.625 --> 00:00:54.700
Multiply both by one hundred.

00:00:55.300 --> 00:00:58.450
Follow your project's logging method for qualifying pieces.

00:01:00.357 --> 00:01:03.198
In this example, a one point five zero meter run yields

00:01:03.213 --> 00:01:07.105
one point two zero meters of recovered core, with zero

00:01:07.120 --> 00:01:09.190
point nine zero meters qualifying.

00:01:13.585 --> 00:01:17.370
Enter eighty for total recovery and sixty for RQD.

00:01:25.145 --> 00:01:28.230
Separate editors also work when you use matching depths.

00:01:31.005 --> 00:01:33.790
Save, close and reopen the borehole log.

00:01:33.805 --> 00:01:37.410
Check both percentages at the intended interval.

00:01:38.085 --> 00:01:41.170
If the template displays bars, check the exact values

00:01:41.185 --> 00:01:45.410
in the editor. Leave unmeasured data blank and enter

00:01:45.425 --> 00:01:48.650
zero only where the run sheet records a measured zero.

00:01:51.965 --> 00:01:55.190
The log now shows the two different percentages against

00:01:55.205 --> 00:02:00.670
one run. For more walkthroughs, open
Ask GAEA Guides in GaeaSynergy.
