WEBVTT

00:00:00.400 --> 00:00:04.810
In this Ask GAEA guide, you will chart contaminant

00:00:04.825 --> 00:00:09.430
concentrations over time. In GaeaSynergy, open Ask GAEA

00:00:09.445 --> 00:00:13.310
and choose Guides. Select Chart contaminant

00:00:13.325 --> 00:00:15.470
concentrations over time in Environmental.

00:00:16.685 --> 00:00:19.390
Keep the source laboratory results available so you can

00:00:19.405 --> 00:00:20.490
verify the chart.

00:00:22.685 --> 00:00:25.050
Open the EDMS project.

00:00:25.645 --> 00:00:29.010
Choose a monitoring well, groundwater as the matrix,

00:00:29.365 --> 00:00:31.570
and one contaminant, such as cadmium.

00:00:33.505 --> 00:00:36.430
Identify the collection dates and sample IDs for the

00:00:36.445 --> 00:00:37.890
period you want to compare.

00:00:39.425 --> 00:00:43.030
Spot-check several results and note any non-detects and

00:00:43.045 --> 00:00:44.070
reporting limits.

00:00:47.885 --> 00:00:51.790
In Migration Center, choose Export data, then the Lab

00:00:51.805 --> 00:00:58.510
Analyses Excel export. On Data, add Sample Number and

00:00:58.525 --> 00:01:03.530
Date Collected. On Results, choose Water, the relevant

00:01:03.545 --> 00:01:05.970
parameter group, and Cadmium.

00:01:07.785 --> 00:01:11.190
On Filter, use Original data only and narrow the scope

00:01:11.205 --> 00:01:12.010
when possible.

00:01:15.885 --> 00:01:19.650
On Options, use a vertical parameter layout and keep

00:01:19.665 --> 00:01:21.190
the non-detect text marker.

00:01:23.185 --> 00:01:26.620
Export the workbook and check the sample IDs, dates,

00:01:26.645 --> 00:01:31.890
and units. Keep the source table as a reference.

00:01:33.845 --> 00:01:36.550
In a separate chart sheet, copy the dates and detected

00:01:36.565 --> 00:01:38.830
concentrations for the selected well.

00:01:42.065 --> 00:01:45.190
Convert any dates stored as text to Excel dates.

00:01:47.245 --> 00:01:50.130
Select the two chart columns and insert a scatter chart

00:01:50.145 --> 00:01:55.770
with markers. Set the horizontal axis to collection

00:01:55.785 --> 00:01:58.530
dates and label the vertical axis with the

00:01:58.545 --> 00:02:04.310
concentration unit. Leave non-detects out of the

00:02:04.325 --> 00:02:06.710
detected series while keeping their records and

00:02:06.725 --> 00:02:08.590
reporting limits in the source table.

00:02:12.205 --> 00:02:14.930
Compare at least two plotted points with the original

00:02:14.945 --> 00:02:20.850
laboratory records. Confirm that unequal intervals show

00:02:20.865 --> 00:02:23.450
up as unequal spacing on the date axis.

00:02:25.425 --> 00:02:28.210
Keep distinct observations on the same day and check

00:02:28.225 --> 00:02:30.890
that a non-detect has no plotted concentration.

00:02:33.065 --> 00:02:37.494
Save the workbook. More guides are available in Ask GAEA.
