WEBVTT

00:00:00.440 --> 00:00:04.625
In this guide, you will import
laboratory results from Excel into

00:00:04.645 --> 00:00:08.025
EDMS in GaeaSynergy.

00:00:08.045 --> 00:00:13.385
Start by clicking Ask GAEA and choosing
Import laboratory results from Excel

00:00:13.405 --> 00:00:14.300
in Guides.

00:00:17.507 --> 00:00:22.332
Open the editable project that received
the samples.

00:00:22.352 --> 00:00:29.272
I am using EDMS Example and one
groundwater sample from the demo round.

00:00:29.292 --> 00:00:35.292
On the project Dashboard, open Tools and
choose Migration Center.

00:00:35.312 --> 00:00:38.012
Click Import data.

00:00:38.032 --> 00:00:42.392
Choose Lab analyses and geotechnical
tests, then Excel - lab data, and

00:00:42.412 --> 00:00:43.507
click Continue.

00:00:47.073 --> 00:00:50.938
Before importing, match the sample
number in the workbook to the sample

00:00:50.958 --> 00:00:52.718
in your project.

00:00:52.738 --> 00:00:58.478
Check that the sample has the correct
default laboratory.

00:00:58.498 --> 00:01:04.438
This workbook has two result rows for
DEMO-GW-2.

00:01:04.458 --> 00:01:08.858
Each row has a parameter, a numeric
result, its units, and a

00:01:08.878 --> 00:01:11.978
separate detection flag.

00:01:11.998 --> 00:01:15.218
Browse to the Excel workbook.

00:01:15.238 --> 00:01:18.793
When it loads, the wizard opens Map
fields.

00:01:20.840 --> 00:01:24.925
Use the Select column for Sample Number.

00:01:24.945 --> 00:01:31.565
On the Excel tab, select the two data
cells in column A, below the heading.

00:01:31.585 --> 00:01:35.265
Click the check mark to use that range.

00:01:35.285 --> 00:01:41.265
Map Parameter, Result, Units, and
Detectable to the corresponding columns.

00:01:41.285 --> 00:01:49.405
Map EQL and MDL when the lab provides
them.

00:01:49.425 --> 00:01:52.465
Keep the mapped ranges aligned.

00:01:52.485 --> 00:01:56.600
All seven ranges here start on row two
and end on row three.

00:01:59.407 --> 00:02:04.772
Click Next to check the project, row
count, and mapped ranges.

00:02:04.792 --> 00:02:10.112
Leave Save lab results with no
associated samples clear when every

00:02:10.132 --> 00:02:14.332
sample number should match an existing
record.

00:02:14.352 --> 00:02:17.612
Go back to Map fields and click Save
Script.

00:02:17.632 --> 00:02:23.347
When you use the script again, verify
the worksheet and ranges.

00:02:25.373 --> 00:02:29.718
When the review matches the workbook,
click Import once.

00:02:29.738 --> 00:02:35.178
Running it again can add duplicate
results.

00:02:35.198 --> 00:02:40.858
On the Results page, check the imported,
skipped, and error counts.

00:02:40.878 --> 00:02:44.278
If anything was skipped, check the
sample ID and the report

00:02:44.298 --> 00:02:47.418
before retrying.

00:02:47.438 --> 00:02:49.733
Close the wizard and return to the
project.

00:02:52.507 --> 00:02:56.712
Open the groundwater sample and choose
Lab Analyses.

00:02:56.732 --> 00:03:02.412
Open the metals analysis and select
Results to check the cadmium value,

00:03:02.432 --> 00:03:05.492
units, and limits.

00:03:05.512 --> 00:03:08.552
Open the lead analysis.

00:03:08.572 --> 00:03:13.532
The Results tab displays N D for not
detected, which matches Detectable set

00:03:13.552 --> 00:03:15.572
to No in the workbook.

00:03:15.592 --> 00:03:21.292
When the saved results match the
workbook, return to Ask GAEA Guides for

00:03:21.312 --> 00:03:22.527
the next walkthrough.
