WEBVTT

00:00:00.400 --> 00:00:03.950
In this Ask GAEA guide, you will link field duplicates

00:00:03.965 --> 00:00:07.630
and blanks and verify the Sample QA/QC table.

00:00:08.865 --> 00:00:11.990
In GaeaSynergy, open Ask GAEA and choose the

00:00:12.005 --> 00:00:15.650
Environmental guide. Keep your field log, chain of

00:00:15.665 --> 00:00:18.690
custody, and quality control pairing record handy.

00:00:21.065 --> 00:00:23.850
Open the project and locate the three records under

00:00:23.865 --> 00:00:25.930
Samples on the project Dashboard.

00:00:26.745 --> 00:00:29.290
Match the field duplicate to its original using the

00:00:29.305 --> 00:00:32.910
pairing records. Verify which round or batch the blank

00:00:32.925 --> 00:00:36.750
covers. Each record should have its own sample number.

00:00:40.225 --> 00:00:44.950
In each sample record, open Lab Analyses.

00:00:44.965 --> 00:00:48.330
Press F2 in the value cell and select the configured

00:00:48.345 --> 00:00:50.250
quality control sample type.

00:00:51.825 --> 00:00:54.090
For the duplicate, choose its original in Parent

00:00:54.105 --> 00:00:58.870
Sample. Assign a parent to the blank only if the field

00:00:58.885 --> 00:01:04.370
records specify one. Enter the documented sequence ID,

00:01:04.685 --> 00:01:05.930
save, and verify.

00:01:09.465 --> 00:01:12.270
Open the Sample Collection task for the round.

00:01:13.965 --> 00:01:17.210
On Stations and Samples, use Link under Samples to

00:01:17.225 --> 00:01:19.690
select the original, duplicate, and blank.

00:01:22.465 --> 00:01:24.570
A link can update the sample immediately.

00:01:26.625 --> 00:01:29.490
Check the existing task before agreeing to reassign a

00:01:29.505 --> 00:01:33.470
sample. Verify the sample numbers, media, and dates

00:01:33.485 --> 00:01:35.050
before closing the task.

00:01:38.125 --> 00:01:41.590
In Migration Center, choose Export data and Sample

00:01:41.605 --> 00:01:47.730
QA/QC Table. On Data, clear Summary and select Sample

00:01:47.745 --> 00:01:52.190
Number, QC Sample Type, Task, and Date Collected.

00:01:56.105 --> 00:01:58.610
Clear All Tasks and choose the collection task.

00:02:00.345 --> 00:02:01.830
Add the date range if needed.

00:02:03.685 --> 00:02:05.930
Review the settings and export the workbook.

00:02:09.345 --> 00:02:12.550
Open the workbook and reconcile each row with the field

00:02:12.565 --> 00:02:18.950
log. If a sample is missing, check its task link,

00:02:19.005 --> 00:02:21.230
media, collection date, and filters.

00:02:23.325 --> 00:02:26.050
Verify Parent Sample and the quality control sequence

00:02:26.065 --> 00:02:27.570
in the original records.

00:02:29.705 --> 00:02:31.690
Keep the workbook and field records together.

00:02:32.345 --> 00:02:34.050
Find more in Ask GAEA Guides.

