WEBVTT

00:00:00.400 --> 00:00:03.750
In this Ask GAEA guide, you will enter a Proctor

00:00:03.765 --> 00:00:07.030
compaction test and check the moisture-density curve.

00:00:08.065 --> 00:00:11.670
In GaeaSynergy, open Ask GAEA and choose the Proctor

00:00:11.685 --> 00:00:16.090
guide under Geotechnical. Have the lab test method,

00:00:16.325 --> 00:00:18.430
mold dimensions, and measurements ready.

00:00:20.365 --> 00:00:22.570
Open the project and find the sample on the Project

00:00:22.585 --> 00:00:26.150
Dashboard. Create a Geotechnical Test.

00:00:27.125 --> 00:00:29.490
Choose Soil and Aggregates, then Compaction.

00:00:29.505 --> 00:00:33.690
Name the test, match the sample number, and select a

00:00:33.705 --> 00:00:36.110
template that includes the compaction curve.

00:00:39.865 --> 00:00:41.830
Record the test date and methodology.

00:00:44.385 --> 00:00:48.490
On Compaction Information, set the length, mass, unit

00:00:48.505 --> 00:00:50.370
weight, and density units.

00:00:53.045 --> 00:00:56.870
Enter the method, preparation method, rammer type, mold

00:00:56.885 --> 00:01:00.810
diameter, mold height, and empty mold mass from the lab

00:01:00.825 --> 00:01:04.330
record. Enter the sample’s specific gravity if your

00:01:04.345 --> 00:01:06.650
report uses a zero-air-voids curve.

00:01:10.705 --> 00:01:14.470
On Compaction Data, enter one soil and mold mass for

00:01:14.485 --> 00:01:17.970
each compaction point. With the correct set selected,

00:01:18.305 --> 00:01:22.390
enter the wet soil and can mass, dry soil and can mass,

00:01:22.445 --> 00:01:23.710
and empty can mass.

00:01:27.325 --> 00:01:30.390
Use Add Measurement for another can in the same set.

00:01:33.005 --> 00:01:36.310
After the last reading, switch sets to refresh the fit.

00:01:39.685 --> 00:01:43.450
Open Results. Compare optimum moisture content and

00:01:43.465 --> 00:01:46.950
maximum dry density or dry unit weight against the

00:01:46.965 --> 00:01:52.650
worksheet. Check that distinct measured water contents

00:01:52.665 --> 00:01:54.610
fall on both sides of the peak.

00:01:57.625 --> 00:02:00.550
If the fit peaks outside the measured range, review the

00:02:00.565 --> 00:02:01.690
readings and units.

00:02:04.985 --> 00:02:08.370
Click OK to open the report, then save the test.

00:02:11.105 --> 00:02:14.330
Check the sample number, plotted points, peak values,

00:02:14.345 --> 00:02:18.290
and axis units. Keep the lab worksheet and test method

00:02:18.305 --> 00:02:22.530
with the report. Find more step-by-step walkthroughs in

00:02:22.545 --> 00:02:23.870
Ask GAEA Guides.

