WEBVTT

00:00:00.400 --> 00:00:03.610
This Ask GAEA guide shows how to compare laboratory

00:00:03.625 --> 00:00:05.990
results with project criteria.

00:00:06.665 --> 00:00:10.640
In GaeaSynergy, open Ask GAEA, then Guides.

00:00:11.605 --> 00:00:14.410
Under Environmental, select Review laboratory results

00:00:14.425 --> 00:00:18.350
against project criteria. Have your laboratory report

00:00:18.365 --> 00:00:20.670
and project-approved criteria ready.

00:00:23.565 --> 00:00:28.210
Open EDMS Example. On the project Dashboard, open an

00:00:28.225 --> 00:00:31.370
analysis from Lab Results and select Results.

00:00:32.745 --> 00:00:35.770
Confirm the sample number, parameter, and units against

00:00:35.785 --> 00:00:41.090
the laboratory report. Under Display Limit, choose the

00:00:41.105 --> 00:00:44.050
regulation and limit category that apply to this sample.

00:00:47.385 --> 00:00:50.450
Select the cadmium result to see its quantitation and

00:00:50.465 --> 00:00:53.850
detection limits. Compare the concentration with the

00:00:53.865 --> 00:00:55.590
criterion in the same units.

00:00:57.405 --> 00:01:00.630
An exceedance flag depends on the comparison rule, such

00:01:00.645 --> 00:01:05.830
as greater than. Review non-detects, missing limits,

00:01:06.065 --> 00:01:08.410
and results with reporting limits above the criterion

00:01:08.425 --> 00:01:09.250
separately.

00:01:13.225 --> 00:01:17.290
Close the analysis. Choose File, New, Report Table,

00:01:17.765 --> 00:01:23.050
then Lab Analyses. On Data, name the table and add

00:01:23.065 --> 00:01:28.310
Sample Number. On Results, choose Water for the matrix,

00:01:28.825 --> 00:01:32.270
select the relevant parameter group, and add Cadmium as

00:01:32.285 --> 00:01:33.530
a named result row.

00:01:36.505 --> 00:01:39.310
Press Tab after choosing a field to commit it.

00:01:41.445 --> 00:01:44.010
On Regulations, include the approved limit.

00:01:45.825 --> 00:01:48.430
If the same limit applies to every sample and your

00:01:48.445 --> 00:01:51.690
parameters run vertically, set Regulation Titles to

00:01:51.705 --> 00:01:57.270
Above Data. In Options, check the units and comparison

00:01:57.285 --> 00:02:02.490
rule. In Format, check the exceedance and non-detect

00:02:02.505 --> 00:02:07.230
styles. Choose a new Excel workbook, review the

00:02:07.245 --> 00:02:08.670
settings, and export.

00:02:13.445 --> 00:02:16.930
Open the workbook. Check that the sample IDs, units,

00:02:16.945 --> 00:02:18.590
and limit match the report.

00:02:21.565 --> 00:02:24.450
Compare a flagged value and a value below the limit.

00:02:27.005 --> 00:02:30.250
Record which criterion and comparison rule you used,

00:02:30.425 --> 00:02:32.770
and keep the checked workbook with the lab report.

00:02:34.665 --> 00:02:37.614
Find more walkthroughs in Ask GAEA Guides.
