WEBVTT

00:00:00.440 --> 00:00:03.145
Welcome to Ask GAEA.

00:00:03.165 --> 00:00:07.385
This guide shows how to plan a sampling
round in GaeaSynergy and print the

00:00:07.405 --> 00:00:09.105
chain of custody.

00:00:09.125 --> 00:00:14.845
Click Ask GAEA, open Guides, and choose
Plan a sampling round and print the

00:00:14.865 --> 00:00:15.800
chain of custody.

00:00:18.773 --> 00:00:22.998
From the full Dashboard, open your EDMS
project.

00:00:23.018 --> 00:00:29.298
We will use EDMS Example for a one-time
groundwater round.

00:00:29.318 --> 00:00:33.658
On the Project Dashboard, identify the
stations for this round.

00:00:33.678 --> 00:00:38.818
This example uses two existing
monitoring stations.

00:00:38.838 --> 00:00:43.758
Before setting up the task, confirm the
collection date, receiving laboratory,

00:00:43.778 --> 00:00:47.793
requested analyses, and the chain of
custody form the lab accepts.

00:00:49.673 --> 00:00:52.558
On the New menu, choose Task.

00:00:52.578 --> 00:00:59.138
In Task Information, set Type to Sample
Collection.

00:00:59.158 --> 00:01:04.398
On the Information tab, select the Name
cell and press F2 to edit.

00:01:04.418 --> 00:01:08.418
Give the task a name you can find later.

00:01:08.438 --> 00:01:11.958
Check the Start Date against your plan.

00:01:11.978 --> 00:01:16.918
Set Reoccurring to No for a one-time
round.

00:01:16.938 --> 00:01:20.073
For a recurring task, verify the next
collection date.

00:01:22.573 --> 00:01:26.118
Open Sampling Defaults.

00:01:26.138 --> 00:01:29.598
Choose the sample media and collection
method, then check the

00:01:29.618 --> 00:01:32.638
Default Laboratory.

00:01:32.658 --> 00:01:37.138
This example uses Groundwater and a
Bladder Pump.

00:01:37.158 --> 00:01:41.458
Under Lab Analyses, click Add.

00:01:41.478 --> 00:01:44.938
Choose the requested parameter, or
choose Individual Parameter to look

00:01:44.958 --> 00:01:49.338
up one analyte.

00:01:49.358 --> 00:01:52.858
Use Lookup Container to review the
container, size, and

00:01:52.878 --> 00:01:55.918
preservative fields.

00:01:55.938 --> 00:01:59.813
Confirm those requirements with the
receiving lab, then click OK.

00:02:01.407 --> 00:02:07.112
Open Stations/Samples, and choose Link
under Stations.

00:02:07.132 --> 00:02:12.912
Select the first station and repeat for
each additional station in the round.

00:02:12.932 --> 00:02:18.132
If GaeaSynergy asks to link unassigned
station samples, choose No unless those

00:02:18.152 --> 00:02:21.752
samples belong to this round.

00:02:21.772 --> 00:02:26.092
The two linked stations should appear in
the top list.

00:02:26.112 --> 00:02:29.372
Click OK to save the task.

00:02:29.392 --> 00:02:32.447
Use Open, then Task, to reopen your
round.

00:02:34.107 --> 00:02:38.832
In the saved task, click Chain of
Custody.

00:02:38.852 --> 00:02:42.792
Choose the form accepted by your lab.

00:02:42.812 --> 00:02:49.332
This example uses the generic letter
template for a proof copy.

00:02:49.352 --> 00:02:53.672
Check the sample date and fill options.

00:02:53.692 --> 00:02:59.492
Include existing samples only after you
verify that they belong to the round.

00:02:59.512 --> 00:03:03.312
For planned samples, set the prefix,
starting number, and samples

00:03:03.332 --> 00:03:05.072
per station.

00:03:05.092 --> 00:03:11.292
Turn on Increment sample number across
stations for unique sequential IDs.

00:03:11.312 --> 00:03:19.232
Click Print, verify the printer in
Excel, and confirm.

00:03:19.252 --> 00:03:24.207
To keep an editable Excel copy, select
Save to file and click Save.

00:03:27.540 --> 00:03:32.625
Compare the printed sample IDs with the
round list and the labels.

00:03:32.645 --> 00:03:40.145
The two planned IDs here are DEMO-GW-1
and DEMO-GW-2.

00:03:40.165 --> 00:03:44.745
Check the project, collection date,
media, analyses, and the custody

00:03:44.765 --> 00:03:47.645
signature fields before the lab handoff.

00:03:47.665 --> 00:03:52.845
You now have a task and a chain of
custody for the round.

00:03:52.865 --> 00:03:56.040
Open the Guides tab in Ask GAEA for more
walkthroughs.
