<< Click to Display Table of Contents >> Water Content (Not in Oil & Gas) |
Water Content graphs are used to display the water content, plastic limit, and liquid limit.
There are several ways to edit water content data, either:
•click on the water content column on the log
•double click on the water content object on the sidebar
•select Edit > Water Content
•or select Popup > Water Content
After this the Water Content Data form will be displayed. At the bottom of this form there are buttons to move to the first, previous, next, and last measurement or to add and delete measurements.
(The appearance of the form will differ slightly depending on if it is WinLoG or WinLoG RT)
The following information can be edited on this form:
Depth: This is the depth of the water content measurement.
Water Content: This is the water content of the sample.
Plastic Limit: This is the plastic limit of the sample.
Liquid Limit: This is the liquid limit of the sample.