WinLoG Environmental Test Pit Example

WinLoG TP-01 environmental test pit log example View Full Log
TP-01 Environmental Test Pit Log
12 ft Test Pit 6 Grab Samples 1 Warning

WinLoG Environmental Test Pit Example

A complete shallow-excavation record combining pavement and fill, native soil, grab samples, USCS classifications, PID/VOC screening, seepage, excavation observations, photographs, and restoration details.

TP-01 Environmental Test Pit represents an environmental assessment at a former service-station property in Kitchener, Ontario. The 12 ft excavation progresses from asphalt and granular base through heterogeneous fill and petroleum-impacted silty sand into native silty clay and dense sandy silt till.

The validation report records 100% completeness, Good quality, and an 84% confidence score. One warning identifies the 146 ppm PID/VOC result at 4.75 ft for confirmatory review; no errors were reported.

Environmental Investigation US Customary Units PID/VOC Screening Groundwater Seepage Validation: Warnings
Capabilities Demonstrated

What This Environmental Test Pit Example Shows

Shallow Profile

  • Depth and elevation scales
  • Six continuous material intervals
  • Graphic lithology patterns
  • Pavement and granular base
  • Fill and native-soil transitions
  • USCS classifications

Sampling

  • Six depth-linked grab samples
  • Sample IDs and intervals
  • Moisture and consistency
  • Sample-specific classifications
  • Laboratory submission note
  • Field-to-lab traceability

Field Screening

  • PID/VOC results from 1.2 to 146 ppm
  • Petroleum odour observations
  • Localized black staining
  • Impacted interval identification
  • Elevated-result warning
  • Confirmatory testing recommendation

Field Documentation

  • Excavation method and dimensions
  • Seepage at 6.8 ft
  • Sidewall-stability observations
  • Photo references
  • Termination conditions
  • Backfill and pavement restoration

From Surface Construction to Native Soil

The profile begins with asphalt and granular base, passes through fill containing brick and concrete fragments, and reaches a petroleum-impacted silty-sand interval between 3.5 and 7.0 ft. Below this zone, the excavation encounters native wet silty clay followed by dense sandy silt till with gravel and cobbles.

The 146 ppm PID/VOC reading at 4.75 ft produces one appropriate validation warning. The log documents that sample TP1-03 was submitted for BTEX and petroleum-hydrocarbon analysis, demonstrating how WinLoG connects field observations, screening results, and follow-up decisions.

Download the Complete Example

Download the files individually. The XML template and test-pit log can be imported into WinLoG Version 6 and customized for environmental assessments, brownfield investigations, spill response, and shallow subsurface programs.

Included in the Example

  • Professional environmental test-pit PDF
  • Automated validation report
  • Reusable test-pit XML template
  • Complete test-pit XML data
  • Lithology, samples, PID/VOC, seepage, excavation observations, and restoration details
Applications

Who This Example Is For

Environmental Consultants

Documents shallow soil conditions, evidence of impacts, field screening, sample collection, groundwater seepage, and laboratory follow-up.

Brownfield Teams

Provides a concise record for redevelopment investigations, due diligence, source-area assessment, remedial planning, and excavation oversight.

QA/QC Reviewers

Supports coordinated review of stratigraphy, sample depths, screening results, visible impacts, confirmatory testing, and completeness.

Customize This Environmental Test Pit Example

WinLoG templates can be adapted for company standards, regulatory programs, and project-specific field forms. Headers, sample columns, screening datasets, lithology, excavation observations, photographs, and validation rules can all be tailored to environmental workflows.

Contact GAEA Technologies